Conveyance control and indication system
The system provides:
-
Two-way voice communication between the hoist operator and the personnel at the conveyance roof or in the cage
-
Issuing motion commands to the drive room from the device installed at the conveyance roof or in the cage
-
Issuing EMERGENCY STOP and LOCK signals to the hoist control circuit by the personnel at the conveyance roof or in the cage in order to stop or prevent hoist motion
-
Signal indication by engaging a respective relay in the central station cabinet and displaying a message at the hoist operator’s display, both with sound alarm
-
Receiving hoist status (GO, STOP) radio signals from the hoist building equipment at the cage roof and subsequent light indication thereof
-
Issuing a sound alarm to announce recording of the communication between the operator and the personnel in the cage or at the conveyance roof by means of a voice recorder installed in the hoist room
-
Data channel to exchange digital data between the cage/skip equipment and the plant room
-
Uninterrupted automatic performance monitoring of all system devices and components
-
Issuing an automatic hoist stop signal upon loss of connection and conveyance trip, to be processed by the hoist control circuit as provided for by the workflow
-
Uninterrupted monitoring of the battery level and indication of battery discharge to the hoist operator
-
Data output to the daily log; the Customer may use the log unedited to arrange the log in the order preset by the Customer
System scope for two-cage machine:
The conveyance control and indication system is a set of items located in various points at the hoist, interconnected to act as intended.
Main performance specifications
Property |
Value |
---|---|
Transceiver frequency range, GHz |
2.4002 ... 2.4785 |
Central station: |
|
Dimensions, mm |
540×520×218 |
Feed voltage, V |
220 VАС |
Ex rating |
[Ex ia Ma] I |
Enclosure protection rating |
IP54 |
Hoist operator’s indication panel: |
|
Dimensions, mm |
400×250×150 |
Feed voltage, V |
24 VDС |
Enclosure protection rating |
IP54 |
UOPD-01 deflection sheave platform data processing and transfer unit (for two conveyances): |
|
Dimensions, mm |
430×430×244 |
Feed voltage, V |
12 VDС |
Ex rating |
PO Ex ia I Ma |
Enclosure protection rating |
IP65 |
SK-02 cage station: |
|
Dimensions, mm |
554×550×218 |
Feed voltage, V |
12 VDС |
Ex rating |
PO Ex ia I Ma |
Enclosure protection rating |
IP65 |
Power supply: |
|
Dimensions, mm |
330×210×198 |
Feed voltage, V |
12 VDС |
Ex rating |
PO Ex ia I Ma X |
Enclosure protection rating |
IP65 |
PSSK-01 cage indication and communication station: |
|
Dimensions, mm |
75×285×75 |
Feed voltage, V |
12 VDС |
Ex rating |
PO Ex ia I Ma |
Main system components:
-
Central station
-
Hoist operator’s indication panel
-
Deflection sheave platform data processing and transfer unit with an antenna assembly
-
Cage station with an antenna assembly
-
Cable slack sensors, cage gate sensors, arresters
Versions of the system components shall be selected on the basis of a requirements specification and a datasheet.
Advantages over similar systems:
-
Higher interference resistance
-
Big amount of data transferred from the conveyance
-
Ability to process analogue and pulse signals from the sensors installed at the conveyance, which allows real-time monitoring of wire condition
-
Possibility to control conveyance equipment from the surface by a wireless communication channel
-
The system can uninterruptedly monitor the status and performance of all connected devices and sensors. Unit input statuses can be checked at the respective page
-
Loss of connection or sensor fault is indicated with a text message at the operator’s display
-
Configuring from the operator’s panel: a sensor may be excluded or other settings can be made in the password protected settings menu
Conveyance control and indication system block diagram