Conveyor load measurement module

Conveyor load measurement module

Environment conditions:

  • Underground excavations at mines, including salt mines, with fresh air inflow ventilation by general mine depression where standard mining electrical equipment may be used

  • Industrial atmosphere type II

  • Atmospheric pressure: (84.0-106.7) kPa

  • Dust concentration in air: max. 500 mg/m3

  • Altitude: 1000m below sea level to 1000m above sea level

  • Climatic version: U5 (temperate); minimum ambient temperature: +10°C; maximum RH: (98±2)% at (25±2)°С

Main performance specifications

Property

Value

Feed voltage, V

24

Analogue output:

current range, мА

4-20

accuracy, %

±1

Operating range, mm

70-1000

Enclosure protection rating

IP54

Dimensions (diameter × height), mm

50×144

Weight, kg, max.

1.1

Version

RN2


Statement of conformity to standard mining version by Belgorkhimprom No.562.3.2022 BY valid till 24/05/2025